TU Berlin

Electrical Energy Storage TechnologyChair

Page Content

to Navigation

Prof. Dr.-Ing. Julia Kowal

Julia Kowal
Lupe

Room: EMH 163

Address: 

Einsteinufer 11

Sec. EMH 2

10587 Berlin

Phone: +49 (0)30 314-25394

Fax:     +49 (0)30 314-21133

E-mail:

Consultation hours: On Mondays 9 - 10 h and on appointment. In summer semester 2022 (25.4.-18.7.), the consultation hour will be from 10-11 h.

In most weeks, I am in the office on mondays, so a personal meeting is possible again. To be sure, please ask before you come. Alternatively, you can phone me or we can arrange a Zoom meeting.

Vita


CV
since 03/2014
Chair of Electrical Energy Storage Technology at the TU Berlin
01/10 - 02/14
Senior engineer at the department of Electrochemical Energy Conversion and Storage Systems, ISEA, RWTH Aachen
2010
PhD at RWTH Aachen, Topic: "Spatially-resolved impedance of nonlinear inhomogeneous devices - using the example of the lead-acid battery"
04/06-05/06
Visiting researcher at the company Exide in Azuqueca de Hénares, Spain
10/05-12/05
Visiting Researcher at the research centre RISØ in Roskilde, Denmark
11/04-12/09
Research assistant at the department of Electrochemical Energy Storage Conversion and Systems at the Institute For Power Electronics and Electrical Drives (ISEA), RWTH Aachen
10/99-11/04
Studies of electrical engineering at RWTH Aachen Diploma thesis: "Investigation of the thermal behaviour of electrochemical energy storage systems in vehicle on-board power supplies"

 

 

Awards and Scholarships
2006
Herbert-Kind-Price of ETG in the VDE
2006
Brigitte-Berkenhoff-Price for the best graduate in the field of electrical engineering at RWTH Aachen
2002
Aachen's VDE price
2001-2004
Sponsorship through the Prof. Dr. Koepchen Merit Foundation (RWE)

Publications

The effects of cell configuration and scaling factors on constant current discharge and dynamic charge acceptance in lead-acid batteries
Citation key BAUKNECHT2022103667
Author S. Bauknecht and J. Kowal and B. Bozkaya and J. Settelein and E. Karden
Pages 103667
Year 2022
ISSN 2352-152X
DOI https://doi.org/10.1016/j.est.2021.103667
Journal Journal of Energy Storage
Volume 45
Abstract The active materials of batteries are often tested and selected at the cell level, which prevents comparability to battery-level performance. In the case of a typical lead-acid battery used in a vehicle, the performance after a few months in operation is not necessarily the same as it was during cell-level tests. The goal of this manuscript is to outline the most common reasons for the divergence in test results between cell-level tests and commercial batteries with respect to dynamic charge acceptance (DCA). To do so, this study tested 12 V-70 Ah enhanced flooded batteries (EFB) for their DCA properties. Afterwards, these batteries were dissembled to extract three 2 V test cells, some with a lower number of plates (3P2N and 2P1N). The aim of this investigation was to determine how the DCA of the original battery was affected by changing the plate count and the ratio between the positive active mass, the negative active mass, and the electrolyte by using industrially manufactured cell components – rather than introducing sources of errors by using handmade cells. Both the test batteries and the test cells were subjected to two different constant current discharge tests: the reserve capacity (RC) test and the C20 test. The DCA test according to Japanese Standard SBA S0101 2014 was also conducted. It was particularly important to identify operational conditions and scaling factors (e.g. voltages, currents, and acid densities) on the cell level – for cells with and without lower plate counts. Currently, these are only defined for battery testing according to standard test procedures. Our test cell design, with a reduced, asymmetric set of plates, generated an acid surplus and a PAM surplus, which in turn had major effects on steady-state properties such as the constant current discharge (as the RC test and C20 test showed). DCA battery and cell-level results are not comparable in terms of absolute values, especially for cells with lower plate count. The DCA results for single cells are systematically better for a lower plate count, which may be attributed to excess acid volume.
Link to publication Download Bibtex entry

Navigation

Quick Access

Schnellnavigation zur Seite über Nummerneingabe